From: Influence of the polyester non-wovens production type on their thermal and flammability properties
Name | Thermal conductivitya k, (W/mK) | Volumetric heat capacitya cp, (J/m3K) | Thermal diffusivitya 𝛼, (m2/s) | Specific heat resistanceb, R, m.K/W |
---|---|---|---|---|
Sample 1 | 0.0393 ± 0.00057 | 0.0630.106 ± 0.0015.106 | 0.6250.10−6 ± 0.0116.10−6 | 25.44 |
Sample 2 | 0.0403 ± 0.00059 | 0.0816.106 ± 0.0020.106 | 0.4937.10−6 ± 0.0092.10−6 | 24.81 |