Skip to main content

Table 3 \(FCFR\) of \({x}_{in}\left(t\right)\) and \({x}_{out}\left(t\right)\), using three envelope detection methods

From: FPGA implementation of an improved envelope detection approach for bearing fault diagnosis

Fault characteristic frequency ratio \({\varvec{F}}{\varvec{C}}{\varvec{F}}{\varvec{R}}\)

Envelope detection Methods

\({\varvec{H}}{\varvec{T}}\)

\({\varvec{T}}{\varvec{E}}{\varvec{O}}\)

\({\varvec{I}}{\varvec{T}}{\varvec{E}}{\varvec{O}}\)

Simulated signal \({{\varvec{x}}}_{{\varvec{i}}{\varvec{n}}}\left({\varvec{t}}\right)\)

7.65

11.84

25.93

Simulated signal \({{\varvec{x}}}_{{\varvec{o}}{\varvec{u}}{\varvec{t}}}\left({\varvec{t}}\right)\)

11.61

14.07

36.51