Skip to main content

Table 5 Signal-to-noise ratio for each level of each parameter along with delta value

From: Optimizing the printing parameters for dimensional accuracy of distal femur bone by using Taguchi’s method

Level

Infill pattern

Nozzle temperature

Printing speed

Layer height

Infill density

1

10.788

10.731

10.751

11.197

10.432

2

10.831

10.613

10.666

10.684

10.603

3

10.446

10.390

10.340

10.345

10.585

4

10.023

10.354

10.332

9.862

10.469

Delta

0.808

0.377

0.419

1.335

0.171

Rank

2

4

3

1

5