Table 2 Validation of result with literature

From: Experimental study on the optimal performance of gas turbine (GT) inlet air filtration system for offshore application

Outlet–inlet

Present study @ 10 m/s

Present study @ 5 m/s

[24]

[26]

[31]

[39]

Pt (kPa)

101.80

58.20

215.00

1651.4

30.9

50

Qf (m3/s)

 − 0.83

 − 0.22

 − 0.05

 − 10

 − 450

 − 123

s (kW)

 − 22.29

 − 6.08

 − 7.73

 − 7.73

 − 3

 − 330