Item | Value | Unit |
---|---|---|
Avoided energy to replace the re-boiler by waste heat recovery system | 12.584 | MMBtu/h |
The existing re-boiler loading condition (duty) | 40% | % |
The equivalent full load hours of the re-boiler | 3504 | HRs |
Avoided energy due to existing operations of the re-boiler | 44,096 | MMBtu/year |
Fuel gas cost | 4.75 | US$/MMBtu |
Anticipated energy cost savings | 210,000 | US$/year |
GHG emission reduction | 2340 | Ton CO2-eq/year |