Skip to main content

Table 2 Table of parameters used in the optimal control simulation

From: Optimal control of a grid-connected photovoltaic agricultural water pumping system

Table of parameters

Time horizon

1 day (24 h)

Sampling interval (\(t_s\))

20 min (1/3 h)

N

Number of time samples, 72

\(V_{max}\) farm 1

23,000 l

\(V_{min}\) farm 1

0 l

\(V_{max}\) farm 2

20,000 l

\(V_{min}\) farm 2

0 l

Underground pump power rating

7.5 kW

Booster pump power rating

1.25 kW

Underground pump flow rate

9000 l/h

Booster pump flow rate

5400 l/h

\(w_1\)

0.4

\(w_2\)

0.4

\(w_3\)

0.2

C

Energy cost per kWh for small commercial at US $$0.16