Skip to main content

Table 5 Columns dimensions and reinforcement for 12 floors models

From: Effect of alternative load path design method on preventing progressive collapse and reducing the rehabilitation cost using FEMA-P58

Floors

Col

Type

Case (A)

Case (B)

Dim. (mm)

RFT.—µ%

Dim. (mm)

RFT.—µ%

1st and 2nd

Main

450X450

16T22—3.00%

500X500

16T20—2.01%

Weak

400X400

12T20—2.36%

400X400

12T20—2.36%

3rd and 4th

Main

400X400

12T22—2.85%

450X450

16T22—3.00%

Weak

350X350

12T18—2.5%

350X350

12T18—2.5%

5th and 6th

Main

350X350

12T20—3.08%

400X400

12T22—2.85%

Weak

350X350

12T16—1.97%

350X350

12T16—1.97%

7th, 8th and 9th

Main

350X350

12T16—1.97%

350X350

12T16—1.97%

Weak

300X300

8T18—2.26%

300X300

8T18—2.26%

10th, 11th and 12th

Main

250X250

8T16—2.6%

300X300

8T16—1.78%

Weak

300X300

8T16—1.78%

300X300

8T16—1.78%