Skip to main content

Table 4 System availability in the presence of Fault tolerance factor only

From: Availability and cost–benefit analysis of a fault tolerant series–parallel system with human-robotic operators

Availability \(\boldsymbol{{\overline{H}}_{up}(s)}\)  

Time \(\boldsymbol{(t)}\)  

\(\boldsymbol{C=0.1}\)  

\(\boldsymbol{C=0.3}\)  

\(\boldsymbol{C=0.5}\)  

\(\boldsymbol{C=0.7}\)  

\(\boldsymbol{C=0.9}\)  

0

1.0000

1.0000

1.0000

1.0000

1.0000

5

0.9886

0.9663

0.9448

0.9238

0.9035

10

0.9883

0.9617

0.9321

0.9004

0.8676

15

0.9873

0.9520

0.9079

0.8589

0.8079

20

0.9857

0.9379

0.8751

0.8059

0.7356

25

0.9834

0.9201

0.8363

0.7465

0.6588

30

0.9805

0.8994

0.7936

0.6845

0.5825

35

0.9770

0.8763

0.7486

0.6225

0.5098

40

0.9730

0.8513

0.7025

0.5622

0.4425

45

0.9684

0.8248

0.6563

0.5048

0.3815

50

0.9634

0.7973

0.6108

0.4510

0.3271