Skip to main content

Table 1 The parameters of the simulated DFIG

From: Study the impact of transient state on the doubly fed induction generator for various wind speeds

Parameter

Value

Unit

\({{\varvec{P}}}_{{\varvec{s}}}\)

\(2\times {10}^{6}\)

\(KW\)

\({{\varvec{T}}}_{{\varvec{e}}{\varvec{m}}}\)

12

\(KN.m\)

\({{\varvec{V}}}_{{\varvec{s}}}\)

690

\(V\)

\({{\varvec{n}}}_{{\varvec{n}}{\varvec{o}}{\varvec{m}}{\varvec{i}}{\varvec{n}}{\varvec{a}}{\varvec{l}}}\)

1500

\(\mathrm{r}.\mathrm{p}.\mathrm{m}\)

\(\mathbf{P}\mathbf{o}\mathbf{l}\mathbf{e}\)

2

–-

\({\mathbf{L}}_{\mathbf{r}}\)

\(0.86\times {10}^{-3}\)  

\(mH\)

\({\mathbf{L}}_{\mathbf{s}}\)

\(0.86\times {10}^{-3}\)

\(mH\)

\({\mathbf{R}}_{\mathbf{r}}\)

\(0.025\)

\(ohm\)

\({\mathbf{R}}_{\mathbf{s}}\)

\(0.027\)

\(ohm\)