Skip to main content

Table 3 Representing the minimum requirements for the proportional room ratio of the Egyptian housing code

From: Performative driven form finding in the early design stage

Space

Indicator

Range

Fixed

Variable

Building

Width-length

12 × 12 + 1.2 cantilever

  

Volume

  

 

Number of rooms

   

Floor area

   

Location

Weather file

Alex, Aswan, Cairo

 

WWR

West

10–100%

 

North

10–100%

 

South

10–100%

 

East

10–100%

 

Room (lobby)

Width-length

1.4 M min

  

Room (reception)

Orientation

  

Area

32 m2 (18 M2 min*)

 

Width-length

Min 2.7 m*

 

Height

3 m

 

Room (bathroom)

Orientation

  

Area

4 m2′

 

Width-length

Min 1 m*

 

Height

3 m

 

Room (kitchen)

Orientation

  

Area

6 m2

 

Width-length

Min 1.5 m*

 

Height

3 m

 

Room (bedroom)

Orientation

  

Area

12 M2 min*, 16 m2

 

Width-length

Min 2.7 m*

 

Main

3 m

 

Room (master bedroom)

Orientation

  

Area

16 m2 (12 M2 min*)

 

Width-length

Min 2.7 m*

 

Height

3 m

 

Room (living)

Orientation

  

Area

16 m2

 

Width-length

Min 2.7 m*

 

Height

3 m

 

Green area

Orientation

  

Area

16 m2

 

Width-length

Min 2.7 m*

 

Height

3 m

 

U-value

  

 
  1. Solar heat gain coefficient (SHGC) of 0.60. The building shape coefficient (or shape factor). The ratio between the external surface of a building and its volume.
  2. *Minimum requirements for the Egyptian housing code