Skip to main content

Table 10 Deterioration models [33]

From: A review of optimization techniques and algorithms used for FRP applications in civil engineering

Number of FRP layers

icorr(mA/cm2)

1.0

2.0

3.0

4.0

0

1.15-0.0011t

1.15-0.0020t

1.15-0.0025t

1.15-0.0030t

1

1.46-0.0015t

1.45-0.0025t

1.46-0.0035t

1.45-0.0040t

2

1.58-0.0017t

1.58-0.0028t

1.58-0.0037t

1.58-0.0045t

3

1.70-0.0018t

1.69-0.0029t

1.70-0.0039t

1.69-0.0046t

4

1.80-0.0018t

1.78-0.0030t

1.78-0.0040t

1.78-0.0050t

5

1.90-0.0018t

1.88-0.0031t

1.90-0.0042t

1.88-0.0051t