From: Comparative study of tube to tubesheet welding qualification on heat exchanger
Tube no | Weld layer | Current (Amp) | Voltage (volts) | Travel speed (mm/min) | Avg heat input KJ/mm |
---|---|---|---|---|---|
Tube 1 | RP | 97–98 | 8.8–9.5 | 74 | 0.7233 |
HP | 100–101 | 9.6–10.2 | 64 | 0.932 | |
Tube 2 | RP | 96–97 | 9.0–9.6 | 75 | 0.717 |
HP | 100–101 | 9.2–9.7 | 72 | 0.787 | |
Tube 3 | RP | 96–97 | 8.8–9.2 | 70 | 0.744 |
HP | 100–101 | 9.8–10.8 | 70 | 0.887 | |
Tube 4 | RP | 96–97 | 8.8–9.5 | 74 | 0.715 |
HP | 99–100 | 9.5–10.2 | 57 | 1.036 | |
Tube 5 | RP | 96–97 | 8.8–9.5 | 74 | 0.715 |
HP | 99–100 | 9.5–10.2 | 57 | 1.036 | |
Tube 6 | RP | 95–97 | 8.5–9.4 | 79 | 0.655 |
HP | 100–101 | 9–10 | 67 | 0.855 | |
Tube 7 | RP | 96–97 | 8.6–9.4 | 55 | 0.947 |
HP | 101–102 | 9.2–10 | 83 | 0.660 | |
Tube 8 | RP | 97–98 | 9.2–10.2 | 52 | 1.09 |
HP | 101–102 | 9–9.8 | 81 | 0.706 | |
Tube 9 | RP | 96–97 | 9–9.8 | 55 | 0.989 |
HP | 100–101 | 9.5–10.2 | 68 | 0.873 | |
Tube 10 | RP | 96–97 | 9–9.8 | 55 | 0.989 |
HP | 100–101 | 9.5–10.2 | 68 | 0.873 |