Skip to main content

Table 4 Comparison of temperature rise between CFD results and experimental data

From: Multi-objective optimization of heat sink with multi-cross-ribbed-fins for a motor controller

 

Experimental data ΔT (K)

ΔTCFD (K)

ΔTerror (%)

Measurement point 1

34.93

33.79

−3.26%

Measurement point 2

34.20

33.52

−1.96%