Table 11 Comparison between columns destructions in three units

From: Exergy analysis and performance study for sour water stripper units, amine regenerator units and a Sulphur recovery unit of a refining plant

Columns (regenerator or stripper)
Unit Destructed energy (KW) Total unit destruction (kW) % share of destruction in its unit
MDEA 45% 1937.89 2404.85 80.58
MDEA 22% 1494.27 1908.86 78.28
ARU 25% 13,459.73 16,907.45 79.61
ARU 20% 15,571.65 18,964.53 82.11
SWS1 5028.58 6203.78 81.06