Table 3 Remaining structural capacity and displacement at different failure positions

From: Study on mechanism and influential factors of progressive collapse resistance of base-isolated structure

Working model

Beam mechanism peak (kN)

Beam mechanism displacement (mm)

Catenary peak (kN)

Catenary displacement (mm)

Bearing displacement

Umin

Umax

A1

163.6

20

109.3

142

−22

22

A2

99.7

23

-

-

-

5

A3

157.7

18

112.4

150

−23

21