Skip to main content

Table 3 Experimental results of the effect of laser power, exposure time, and FPP on the diameter, depth, and HAZ of drilled holes, as presented by Design–Expert software

From: Optimization of PC micro-drilling using a continuous CO2 laser: an experimental and theoretical comparative study

No.

Factor 1

Factor 2

Factor 3

Response 1

Response 2

Response3

Run

A: Power (W)

B: Exposure time (s)

B: FPP (mm)

Depth of hole (mm)

Diameter of hole (μm)

HAZ (μm)

1

2

0.15

−4

0.4

500

155

2

2

0.2

−2

0.7

350

102

3

2

0.1

−2

0.4

320

80

4

2

0.15

0

0.8

320

80

5

3

0.1

−4

0.4

565

118

6

3

0.2

−4

0.82

618

206

7

3

0.15

−2

0.65

340

100

8

3

0.15

−2

0.651

341

100.2

9

3

0.15

−2

0.65

341

100

10

3

0.15

−2

0.65

340.7

100.05

11

3

0.15

−2

0.6502

340

100

12

3

0.1

0

0.8

331

80

13

3

0.2

0

1

400

101

14

4

0.15

−4

0.8

616

170

15

4

0.1

−2

1

352

101

16

4

0.2

−2

1

500

202

17

4

0.15

0

1

351

102