Table 10 Experimental and simulated data at 150 °C and 110 °C for H = 115 mm and 155 mm

From: Assessment of liquid and gas impingement cooling fluids with numerical solution for better steel austempering

At D = 10 mm

At D = 40 mm

W-JIC

A-JIC

W-JIC

A-JIC

t(s)

Ts °C

t(s)

Ts °C

t(s)

Ts °C

t(s)

Ts °C

0

450

0

450

0

410

0

410

40

400

120.2

400

39.2

360

91.32

360

80

350

240.2

350

78.4

310

182.64

310

120

300

360.6

300

117.6

260

273.96

260

160

250

480.6

250

156.8

210

356.28

210

200

200

601.8

200

196

160

456.6

160

240

150

721.2

150

235.2

110

547.92

110