Skip to main content

Table 4 Minimum leak path

From: Comparative study of tube to tubesheet welding qualification on heat exchanger

S.no

MLP for P no. 1-8

MLP for P no. 8-8

MLP for P no. 45-45

S.no

MLP for P no. 1-8

MLP for P no. 8-8

MLP for P no. 45-45

1

4.02

2.6

4.31

21

3.90

3.7

3.37

2

4.20

3

3.18

22

3.99

4.1

4.43

3

4.16

3.3

3.95

23

4.15

3.6

4.45

4

3.90

3.5

4.19

24

4.20

4

3.91

5

3.85

3.4

4.32

25

3.65

3.6

4.72

6

4.19

3.6

4.52

26

3.98

3.8

4.24

7

4.35

4

4.11

27

4.20

2.8

4.64

8

4.39

4.1

4.10

28

4.00

2.9

4.62

9

4.03

3.4

3.99

29

3.98

3.1

5.54

10

4.11

4

3.87

30

4.25

2.9

4.86

11

4.00

3.7

4.29

31

4.20

2.7

4.88

12

4.12

3.9

4.32

32

4.25

3.0

4.92

13

4.40

3.4

4.76

33

4.30

3.1

4.52

14

4.41

4

4.17

34

4.35

3.9

5.58

15

4.43

3

4.61

35

4.22

3.7

4.94

16

4.28

3.4

4.36

36

4.27

3.3

4.83

17

4.20

3.5

4.30

37

4.06

2.9

4.51

18

4.35

3.9

4.32

38

4.23

2.9

5.75

19

3.90

3

4.63

39

3.75

3.0

4.58

20

4.13

3.9

3.74

40

4.23

3.9

4.95