From: Numerical validation of pressure and flow characteristics across a control valve in a feed line
% opening | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
Cv* | 0 | 2.09 | 5.13 | 9.03 | 13.43 | 17.75 | 22.07 | 26.29 | 30.66 | 34.95 | 37.27 |
τ | 0 | 0.055 | 0.135 | 0.238 | 0.353 | 0.467 | 0.58 | 0.69 | 0.806 | 0.92 | 0.98 |