From: Numerical validation of pressure and flow characteristics across a control valve in a feed line
Fluid medium | Water | ||||
Working temperature (K) | 298 K | ||||
Inlet nominal pipe size × schedule | DN80, 10S | ||||
Outlet nominal pipe size × schedule | DN80, 10S | ||||
Flow characteristic | Equal percentage | ||||
Pressure rating class, metric | 150# | ||||
End connection | Flanged | ||||
Normal position | Normally close | ||||
Operating conditions | Inlet temprature (K) | 298 K | 298 K | 298 K | 298 K |
Inlet pressure (bar) | 30 | 30 | 5 | 5 | |
Outlet pressure (bar) | 5 | 5 | 2 | 2 | |
Flow-rate (kg/s) | 12 | 2 | 12 | 0.5–0.8 |