From: Performance of concrete beams partially/fully reinforced with glass fiber polymer bars
Concrete type | Sample (ID) | Weight (kg) | Dimension | Failure load (KN) | Fcu (N/mm2) | |||
---|---|---|---|---|---|---|---|---|
Length (mm) | Width (mm) | Height (mm) | ||||||
N.S.C | I | 1 | 8248 | 150 | 150 | 150 | 814 | 36.17 |
2 | 8210 | 152 | 151 | 152 | 777 | 33.85 | ||
3 | 8388 | 152 | 151 | 151 | 795 | 34.62 | ||
II | 1 | 8777 | 154 | 154 | 154 | 777 | 32.76 | |
2 | 8385 | 151 | 152 | 151 | 754 | 32.85 | ||
3 | 8160 | 151 | 149 | 149 | 790 | 35.11 | ||
H.S.C | III | 1 | 8115 | 152 | 150 | 151 | 1631 | 71.53 |
2 | 8270 | 153 | 149 | 150 | 1354 | 59.39 | ||
3 | 7996 | 152 | 148 | 148 | 1211.2 | 53.84 | ||
IV | 1 | 7975 | 149 | 149 | 149 | 1401.6 | 63.13 | |
2 | 7957 | 151 | 147 | 152 | 1599.1 | 72.04 | ||
3 | 7897 | 151 | 147 | 149 | 1580.4 | 71.19 |